Minimum And Maximum Percentage Of Steel In Column Beam Slab And Foundation
What Is The Minimum and Maximum Percentage Of Steel In Column| What Is The Minimum and Maximum Percentage Of Steel In Beam| What Is The Minimum and Maximum Percentage Of Steel In Slab| What Is The Minimum and Maximum Percentage Of Steel In Foundation
What Is The Minimum and Maximum Percentage Of Steel In Column Beam Slab And Foundation
In This Article, I will discuss the Minimum and Maximum % of the steel in the column. What Is The Minimum and Maximum Percentage Of Steel In the Column| What Is The Minimum and Maximum Percentage Of Steel In the Beam| What Is The Minimum and Maximum Percentage Of Steel In the Slab| What Is The Minimum and Maximum Percentage Of Steel In the Foundation|Minimum And Maximum Percentage Of Steel In Column Beam Slab And Foundation
What Is The Minimum and Maximum Percentage Of Steel In Column Beam Slab And Foundation
Percentage of (%) of Reinforcement/Rebar is an important concept in structure design without using the outside and minimum values of a chance of Reinforcement/Rebar it isn’t possible to get the final underpinning details.
After designing the structure model using a primer or software system it’s important to compare the final affair with specifications of maximum and minimal values. Still, Columns, Arbor Roof or floor slab, and foundation exceed the respectable values also the cost of the design increases at the same time it’ll leading to a drop in the strength of the structure, If the Rebar chance or (%) values in shafts.
So it’s important to know the outside and minimum values of sword probabilities in RCC structures.
Percentage (%) of Rebar in Concrete
Rebar chance or %, Rebar in the Beam, Rebar in the Column, Rebar in the Arbor/Roof or Floor Slab, Rebar in the Foundation Chance or % of Rebar in the Building The outside and minimal underpinning values as per the specifications depend upon the factors which are described below
Lading condition
Soil bearing capacity
Height of column and length of Rebar
Size of Rebar
1. Loading Condition
Lading is the first factor that affects the underpinning values of the Horizontal concrete member/beam, column, arbor/roof or slab, and foundation, it’s depending upon the total sum of the cargo( side or graveness). If the sum of the intensity is high also underpinning values increase and if the lading is lower also underpinning values decreases and vice versa. cargo on the structure, colorful loads on the structure, erecting loads, Bending moment due to applied cargo
2. Soil Bearing Capacity
The soil bearing capacity is expressed in kN/m² units this will depend upon the soil condition type in the point. The advanced values of bearing capacity values will give better strength for structure. The three types of soil conditions which are related to the loose, medium, and gemstone soils are taken in the structure design.
For illustration, if we consider the structure design in loose soil condition and which is having lower bearing capacity less quantum of underpinning values is needed.
3. Height of The Column And Length of The Beam
The height of the column and length of the ray is the third factor that affects the underpinning values if dimensions like height and length increase also underpinning values increase to repel the total cargo on the structure.
4. Size of The Rebar
For introductory low-rise structures the 12 mm and 16 mm periphery bars are preferred, if we increase the size of the rebar behind 16 mm the %(percent) of the Rebar increases in the structure design.
Reinforcement/rebar in structure, 12 mm dia, 16 mm dia, bars in concrete mm and 16 mm size of bars Maximum and minimal values
Read More
-
Whats The Thumb Rule And Estimation Of Thumb Rules In Civil Engineering
-
Introduction Of Thumb Rule And Thumb Rule For The Column Steel Structure And Beam
-
Why Using The Crank Bar In Slab Column RCC Beam
-
Load Calculation For Column Beam And Slab Design Calculation
-
How To Calculate The Estimate Of Building Construction
-
Bar Bending Schedule For The Staircase